FD-DA02
4 IN / 4 OUT Module – 6 units DIN rail
Functional characteristics
The FD-DA02 is a module for the acquisition of sensors data and to command actuators devices like sirens, electrical locks, etc with the following characteristics:
• Can be mounted on DIN rails
• Data acquisition from dry contacts (on/off)
• Data acquisition from supervised sensors managing 5 states per sensor (normal, alarm, tamper, cut circuit, short-circuit), and inject pseudo-random interference in order to prevent level detection from the outside
• Able to control resistive and inductive loads (up to 4 loads, from 0.3ADC (0.2 AAC) up to 2.5 ADC (1.8AAC) per channel adding optional relays)
• Output monitoring, with alarm generation in the event of faults
• Able to monitor a FD PA01 power supply module through a suitable connection, for all the main electrical parameters including the battery effectiveness tests
• Visual fault and/or alarm indication
• Connection to FD-BUS through an RJ45 connection
• Double RJ45 connector (internally in parallel) for easy reconnection to the FD-BUS
• Galvanic separation of the FD-BUS backbone from the local reference ground
• Possibility of connecting the FD-BUS remote power supply to the local power supply through jumpers
Protection
The equipment is protected against the following events:
• polarity reversal on the cables (RJ45) connecting to the FD-BUS
• voltage surge in the power supply
• negative voltage peaks at outputs with inductive loads
Modes of Operation
The FD-DA01 module is part of the Orangelink system and can perform the data acquisition functions related to the status of sensors and/or contacts, and control electrolocks and/or turnstiles. The module can operate in two different modes:
• In dry contact (access control) acquisition mode, the module can acquire the status data from 8 contacts.
• In supervised contact acquisition mode (intrusion dtection and access control), the module can acquire the status data from 4 sensors, and manage the 5 possible states (normal, alarm, tamper, cut, short-circuit).
Visual indicators
The FD-DA01 module can give the user indications by means of:¨
• a red LED
• a yellow LED
• a green LED
The most common indications are as follows:
• Green LED, lit steadily when in operation
• Red LED, lit steadily in the event of an alarm and/or fault
• Yellow LED, flashes during communication (one flash per message)
Technical specifications
| Input/Output | Power input:
Inputs (4):
Tamper input:
Outputs (4)
• Alternate current:
Mounting optional relays:
• Alternate current:
Inputs at outputs (4)
|
| Power Supply | Internal circuit:
Optically isolated section on FD BUS:
|
| Interface Hardware | Power supply input
|
| Physical Characteristics | • Working temperature: 0 to 50°C
|
| Audio & Video | Alarm LED (red)
|
| CPU | P89C662 Philips at 11.0592 MHz |
Request more information
If you would like more information on this product please fill in this form. Please make sure you include your name and contact details or we will not be able to get back to you.
Information request on: FD-DA02 |
*Required field |
Privacy Statement. Zucchetti Axess guarantees that the information you submit will be treated in the strictest confidence and in accordance with Italian legislation on data management (Legislative Decree n. 196 of 30 giugno 2003).