FD-DA02

4 IN / 4 OUT Module – 6 units DIN rail

FD-DA02

Functional characteristics

The FD-DA02 is a module for the acquisition of sensors data and to command actuators devices like sirens, electrical locks, etc with the following characteristics:
•  Can be mounted on DIN rails
•  Data acquisition from dry contacts (on/off)
•  Data acquisition from supervised sensors managing 5 states per sensor (normal, alarm, tamper, cut circuit, short-circuit), and inject pseudo-random interference in order to prevent level detection from the outside
•  Able to control resistive and inductive loads (up to 4 loads, from 0.3ADC (0.2 AAC) up to 2.5 ADC (1.8AAC) per channel adding optional relays)
•  Output monitoring, with alarm generation in the event of faults
•  Able to monitor a FD PA01 power supply module through a suitable connection, for all the main electrical parameters including the battery effectiveness tests
•   Visual fault and/or alarm indication
•   Connection to FD-BUS through an RJ45 connection
•   Double RJ45 connector (internally in parallel) for easy reconnection to the FD-BUS
•   Galvanic separation of the FD-BUS backbone from the local reference ground
•   Possibility of connecting the FD-BUS remote power supply to the local power supply through jumpers

Protection

The equipment is protected against the following events:
•  polarity reversal on the cables (RJ45) connecting to the FD-BUS
•  voltage surge in the power supply
•  negative voltage peaks at outputs with inductive loads

Modes of Operation

The FD-DA01 module is part of the Orangelink system and can perform the data acquisition functions related to the status of sensors and/or contacts, and control electrolocks and/or turnstiles. The module can operate in two different modes:
•  In dry contact (access control) acquisition mode, the module can acquire the status data from 8 contacts.
•  In supervised contact acquisition mode (intrusion dtection and access control), the module can acquire the status data from 4 sensors, and manage the 5 possible states (normal, alarm, tamper, cut, short-circuit).

Visual indicators

The FD-DA01 module can give the user indications by means of:¨
•  a red LED
•  a yellow LED
•  a green LED

The most common indications are as follows:
•  Green LED, lit steadily when in operation
•  Red LED, lit steadily in the event of an alarm and/or fault
•  Yellow LED, flashes during communication (one flash per message)

Technical specifications

Input/Output

Power input:
Clamp (removable)
Voltage: from 8VDC to 14VDC
Current: up to 3 Amp


Inputs (4):
Clamp (removable) for supervised contacts and/or dry contacts
Voltage applied: 0VDC to 14VDC
Current supplied: 0 mA to 3 mA (programmable)
The contacts are supervised by means of 3 external resistors with pre-defined values, for detecting the following conditions: Normal, Alarm, Tamper, Cut, Short-circuit.


Tamper input:
Clamp (removable) for tampering with cabinet (dry contact)
Voltage applied: 0VDC to 30VDC
Response threshold: 3VDC
Current supplied: 0.5 mA

Outputs (4)
Open drain type
•  Direct current:
Voltage applied: from 0VDC to 30VDC
Current applied: up to 0.3 ADC

•  Alternate current:
Voltage applied: up to 24 VAC
Current applied: up to 0.2 AAC

Mounting optional relays:
•  Direct current:
Voltage applied: from 0VDC up to 30 VDC
Current applied: up to 2.5 ADC

•  Alternate current:
Voltage applied: up to 24 VAC
Current applied: up to 1.8 AAC

 

Inputs at outputs (4)
While the outputs are in the OPEN state, they can be used as 4 additional digital inputs:
<3V=Contact closed
<3V=Contact open

Power Supply

Internal circuit:
from 8VDC to 14VDC
48 mA nominal (at 14VDC)

Optically isolated section on FD BUS:
From 8VDC to 14VDC
0.8 mA nominal (at 14VDC)

Hardware Interface

Power supply input
FD-BUS (2 RJ45s in parallel)
Remote monitoring input for FD PA01 power supply module
Monitored power outputs (4)
Supervised inputs (4)
Tamper input

Physical Characteristics

•   Working temperature: 0 to 50°C
•   Humidity: up to 90% without condensation
•   Dimensions: 105x85x55mm (6 DIN units)
•   Weight: 190g
•   Mounting: on DIN rail

Audio & Video

Alarm LED (red)
Communication LED (yellow)
Operation LED (green)

CPU

P89C662 Philips at 11.0592 MHz

Request more information

If you would like more information on this product please fill in this form. Please make sure you include your name and contact details or we will not be able to get back to you.

Information request on: FD-DA02

*Required field










 Data Collection Terminals
 Access Control Systems
 Time & Attendance Systems



Please enter the word you see in the image below:


Privacy Statement. Zucchetti Axess guarantees that the information you submit will be treated in the strictest confidence and in accordance with Italian legislation on data management (Legislative Decree n. 196 of 30 giugno 2003).

gototop

Search this site