FD-WA02

Wiegand & serial I/F - 4 units DIN rail

FD-WA02

Functional characteristics

The FD-WA02 is a module designed for interfacing the OrangeLink system with external devices by means of a serial line (RS232 or RS485 or Wiegand).The module has the following characteristics:
•  Designed for mounting on DIN rails
•  Capable of interfacing with a full duplex RS232 line (standard levels) with speed of 300 baud to 115 Kbaud
•  Capable of interfacing with a half duplex RS485 line with speed of 300 baud to 115 Kbaud
•  Capable of interfacing with a Wiegand line with speed of 10 bps to 20 kbps
•  Management of status LEDs for an external Wiegand reader (LED GO, LED STOP, Buzzer)
•  Visual fault and/or alarm indication
•  Connection to FD-BUS through an RJ45 connection
•  Double RJ45 connector (internally in parallel) for easy branching of the FD-BUS connection
•  Galvanic separation of the FD-BUS backbone from the local ground reference
•  Possibility of connecting the FD-BUS remote power supply to the local power supply by means of jumpers

Protections

The equipment is protected against the following events:
•  polarity reversal on the cables (RJ45) connecting to the FD-BUS
•  voltage surge in the power supply

Modes of Operation

FD-WA02 module forms part of the Orangelink link system and is capable of controlling serial printers, acquiring data from Wiegand readers and interfacing with biometric modules, turnstiles, etc.
The asynchronous serial channel can be configured by means of jumpers in two different and mutually exclusive modes:
•  RS232
•  RS485
The Wiegand synchronous serial channel is always active.

Visual indicators

FD-WA02 can give signals to the user by the following means:
•  green LED
•  red LED
•  yellow LED

The most common indications are as follows:
•  Green LED, lit steadily when in operation
•  Red LED, lit steadily in the event of an alarm and/or fault
•  Yellow LED, flashes during communication (one flash per message)

Technical specifications

Communication Ports

Wiegand interface: On RJ45 connector
•  Wiegand inputs (0 and 1) TTL level protected against overvoltage up to +14V
•  Open collector outputs (3) for managing LEDs/buzzers (14V max, 100mA max)
•  Power supply for reader 14V 350mA max

Serial port selector: Serial port selection by means of jumper
•  RS232 (jumper inserted)
•  RS485 (jumper removed)

RS232 interface: On RJ45 connector
•  Level inputs -16V…+16V
•  Level outputs -8V…+8V, 22mA max
•  Speed from 300 baud to 115200 baud

RS485 interface: On removable terminal block
•  Differential input (levels -7V…+12V)
•  Differential output (levels 0V…+5V) 90mA max
•  Speed from 300 baud to 115200 baud

FD BUS connection: 2 RJ45 ports in parallel
•  Differential RS485 serial interface
•  Baud rate (nominal) 115000 baud
Optically insulated floating ground (500V insulation)

Power Supply

Power supply: internal circuit
From 8VDC to 14VDC
75mA rated (at 14VDC)

Power supply:optically isolated section on FD BUS
From 8VDC to 14VDC
0.8mA rated (at 14VDC)

Power supply In
Terminal block (removable)
•  Voltage: From 8VDC to 14VDC
•  Current: up to 1 Amp

Interface Hardware

Connections
•  Input for local power supply
•  FD-BUS (2 RJ45s in parallel)
•  Wiegand input
•  RS232 serial interface
•  RS485 serial interface

Physical Characteristics

•  Working temperature: 0 ↔ 50°C
•  Humidity: up to 90% without condensation
•  Dimensions: 105x69x55mm (4 DIN units)
•  Weight: 110g
•  Mounting: on DIN rail

Audio & Video

Indicator signals
•  Red LED for communication on serial port
•  Yellow LED for communication on FD-BUS
•  Operation LED (green)

CPU

Philips P89C669, 11,0592MHz

Request more information

If you would like more information on this product please fill in this form. Please make sure you include your name and contact details or we will not be able to get back to you.

Information request on: FD-WA02

*Required field










 Data Collection Terminals
 Access Control Systems
 Time & Attendance Systems



Privacy Statement. Zucchetti Axess guarantees that the information you submit will be treated in the strictest confidence and in accordance with Italian legislation on data management (Legislative Decree n. 196 of 30 giugno 2003).

gototop

Search this site