FD-BC01

Power Supply controller – 6 units DIN rail

FD-BC01

Functional characteristics

FD-BC01 is a main power and battery control module belonging to the Orangelink family, with the following characteristics:
•  Designed for mounting on DIN rails
•  Capable of delivering 12V 5A to the field
•  Battery disconnection at 10V for overload protection
•  Output can be connected in parallel with other power supplies
•  Capable of monitoring all the electrical parameters of the battery, including battery efficiency tests
•  Capable of routing up to 64 devices on RS485
•  Visual On/Off indicator for main power supply
•  Fault and/or overload indicator
•  Connection to FD-BUS through an RJ45 connection
•  Predisposition for branching of the FD BUS data connection between pairs of connectors by means of jumpers

Protection

The equipment is protected against the following events:
•  polarity reversal on the cables (RJ45) connecting to the FD-BUS
•  voltage surge in the power supply
•  battery short circuit

Modes of Operation

FD-BC01 can supply power to up to 4 Orangelink system backbones:
•  Each FD-BUS-A/B and FD-BUS C/D pair can be set individually to bypass or open mode
•  In bypass mode, the data lines of the FD-BUS pair are interconnected so as to form a single backbone
•  In open mode, the data lines of the FD-BUS pair are separated so as to form 2 independent backbones

Visual indicators

The FD-BC01 can give signals to the user by the following means:
•  red LED
•  yellow LED
•  green LED
•  buzzer

The most common indications are as follows:
•  Green LED, lit steadily when main power is On
•  Green LED, flashing when main power is Off
•  Red LED, flashing in the event of overload (overvoltage, intensive charge)
•  Red LED, lit steadily in the event of a fault (no voltage at output) or if power is about to go off
•  Yellow LED, flashing during communication (one flash for each message sent)
•  Active buzzer for indicating a battery fault

Technical specifications

Input/Output

Tamper input
Clamp (removable) for tampering with cabinet (dry contact)
•  Voltage applied:  0VDC to 30VDC
•  Response threshold:  3VDC
•  Current supplied:  0.5 mA

Power Supply

Power supply: input voltage
15VDC +/- 3%)

Power supply: optoisolated section FD BUS
Da 8VDC a 14VDC0.8 mA nominali (a 14VDC)

Internal consumption
35mA rated55mA max

Consumption for battery charging
Charging limits can be set by means of jumpers from 0.6A (no jumper inserted) to 4.9A (all jumpers inserted) in steps of 1.1A (each jumper inserted adds 1.1A to the 0.6A that constitute the minimum charging current)

Output voltage
•  From 13VDC to 14.5VDC (with 15V supply voltage)
•  From 10VDC to 13VDC (operating on battery)

Output current
8A max (battery fuse limit)

Fuses
Battery fuse: 8A 250V T (6x36)

Physical Characteristics

•  Working temperature: 0 ↔ 40°C (ventilation by natural convection)
•  Humidity: up to 95% without condensation
•  Dimensions: 105x85x55mm (6 DIN units)
•  Weight: 250g
•  Mounting: on DIN rail

Request more information

If you would like more information on this product please fill in this form. Please make sure you include your name and contact details or we will not be able to get back to you.

Information request on: FD-BC01

*Required field










 Data Collection Terminals
 Access Control Systems
 Time & Attendance Systems



Privacy Statement. Zucchetti Axess guarantees that the information you submit will be treated in the strictest confidence and in accordance with Italian legislation on data management (Legislative Decree n. 196 of 30 giugno 2003).

gototop

Search this site